Agilent E1439 Programmer's Reference

Functions listed alphabetically

age1439_interrupt_restore (on page 145) −restores the interrupt masks to the most recent setting

age1439_interrupt_setup (on page 146) −sets both interrupt parameters age1439_lbus_mode (on page 148) −sets the local bus transmission mode age1439_lbus_mode_get (on page 148) −gets the local bus mode age1439_lbus_reset (on page 150) −resets local bus age1439_lbus_reset_get (on page 150) −gets the local bus mode reset state age1439_meas_control (on page 151) −initiates and controls measurements in multi-

module systems

age1439_meas_init (on page 154) −initiates a measurement without first checking for valid hardware setup

age1439_meas_start (on page 155) −checks for valid hardware setup and then initiates a measurement

age1439_meas_status_get (on page 156) −returns the current measurement status. age1439_options_get (on page 157) −returns the module’s options age1439_product_id_get (on page 158) −returns the module’s product identification

string

age1439_read (on page 159) −reads scaled 32-bit float data from FIFO age1439_read_raw (on page 162) −reads raw data from FIFO

age1439_read64 (on page 159) −reads scaled 64-bit float data from FIFO, specifically for VEE applications

age1439_reference_clock (on page 165) −selects the source of the reference clock age1439_reference_clock_get (on page 165) −gets the source of the reference clock age1439_reference_prescaler (on page 166) −selects prescaling of the reference clock age1439_reference_prescaler_get (on page 166) −gets prescaling of the reference clock age1439_reset (on page 167) −places the module in a known state age1439_reset_hard (on page 168) −resets the module hardware age1439_revision_query (on page 169) −returns strings that identify the date of the firm-

ware revision.

age1439_self_test (on page 170) −performs a self-test on the module and returns the result age1439_serial_number (on page 157) −sets the module’s serial number for product

repair purposes

age1439_serial_number_get (on page 157) −returns the module’s serial number age1439_smb_clock_output (on page 173) −specifies which clock to output from the

SMB clock connectors

age1439_smb_clock_output_get (on page 173) −gets which clock to output from the SMB clock connectors

age1439_state_save (on page 175) −saves the current module state age1439_state_recall (on page 174) −recalls a saved module state age1439_status_get (on page 176) −retrieves module's status register information age1439_sync_clock (on page 178) −selects the source of the sync signal age1439_sync_clock_get (on page 178) −gets the source of the sync signal age1439_sync_direction (on page 179) −selects front or rear panel availability of the sync

signal

age1439_sync_direction_get (on page 179) −gets the state of front or rear panel clock availability

age1439_sync_output (on page 180) −selects the output for the sync signal age1439_sync_output_get (on page 180) −gets the output for the sync signal age1439_trigger_adclevel (on page 183) −specifies the threshold for the ADC trigger age1439_trigger_adclevel_get (on page 183) −gets the trigger threshold age1439_trigger_delay (on page 183) −specifies a pre- or post-trigger delay time age1439_trigger_delay_actual_get (on page 181) −gets the actual delay time from the

70

Page 80
Image 80
Agilent Technologies manual Agilent E1439 Programmers Reference