Agilent E1439 Programmer's Reference

Functions listed alphabetically

age1439_reset

Places the module in a known state.

VXIplug&play Syntax

#include "age1439".h

ViStatus age1439_reset(ViSession id);

Description

age1439_reset returns the module’s internal data structures to the power-up state but does not reset the hardware. This function can be called separately by this function, or may be selected in conjunction with the age1439_init function.

Calling this function halts any measurement or fiber transfer.

Parameters

is the VXI instrument session pointer returned by the age1439_init function.

Comments

The reset values are listed in “Default values” on page 201.

This command takes about 100 ms to complete.

Return Value

AGE1439_SUCCESS indicates that a function was successful.

Values other than AGE1439_SUCCESS indicate an error condition or other important status condition. To determine the error message, pass the return value to “age1439_error_message” on page 102.

See Also

“Commands which halt active measurements” on page 198, “age1439_init” on page 132, “age1439_reset_hard” on page 168