Agilent E1439 Programmer's Reference

Functions listed alphabetically

Functions listed alphabetically

age1439_adc_clock (on page 72) determines the ADC clock source age1439_adc_clock_get (on page 72) gets the ADC clock source age1439_adc_divider (on page 73) determines which divider is applied to the ADC

clock source

age1439_adc_divider_get (on page 73)gets the module's current clock divider state age1439_attrib_get (on page 74) gets low-level attributes of current I/O library session. age1439_cal_get (on page 75) gets last calibration date of specified board age1439_clock_fs (on page 76) provides the module with the frequency of an external

sample clock

age1439_clock_fs_get (on page 76) gets the current external sample clock frequency age1439_clock_recover (on page 77) allows recovery from an out-of-spec external sam-

ple clock

age1439_clock_setup (on page 78) sets all timing parameters for commonly used mea- surement setups

age1439_clock_setup_get (on page 78) gets the current clock setup age1439_close (on page 86) closes the module's software connection age1439_combo_setup (on page 87) a quick way to set blocksize, center frequency, and

signal bandwidth with one function

age1439_data_blocksize (on page 90) determines the size of the output data block age1439_data_blocksize_get (on page 90) gets the output data block size age1439_data_delay (on page 90) determines FIFO delay in continuous mode age1439_data_delay_get (on page 90) gets FIFO delay in continuous mode age1439_data_memsize_get (on page 88) returns module's memory size in megabytes age1439_data_mode (on page 90) selects block mode or continuous mode age1439_data_mode_get (on page 90) gets the data mode

age1439_data_port (on page 90) selects VME bus, local bus or fiber interface for output port transmission

age1439_data_port_get (on page 90) gets the output port designation age1439_data_resolution (on page 90) selects 12 or 24 bits data resolution age1439_data_resolution_get (on page 90) gets the data resolution age1439_data_scale_get (on page 89) gets data scale factor used to convert raw data to

volts

age1439_data_setup (on page 90) sets all format and data output flow parameters age1439_data_spectral_order (on page 90) specifies the spectral order of the output

data.

age1439_data_spectral_order_get (on page 90) gets the spectral order of the output data.

age1439_data_type (on page 90) selects real or complex output data age1439_data_type_get (on page 90) gets output data type age1439_data_xfersize (on page 96) allows a specified amount of data to be read before

an entire block has been acquired age1439_data_xfersize_get (on page 96) gets the data transfer size age1439_driver_debug_level (on page 97) sets the debug level

67

Page 77
Image 77
Agilent Technologies E1439 manual Functions listed alphabetically