Agilent Technologies E1439 manual Initializing and closing

Models: E1439

1 246
Download 246 pages 11.5 Kb
Page 71
Image 71

Agilent E1439 Programmer's Reference

Functions listed by functional group

Initializing and closing

age1439_init (on page 132) initializes the I/O driver for a module age1439_close (on page 86) closes the module's software connection

Analog setup

age1439_input_setup (on page 141) sets all the analog input parameters

age1439_input_alias_filter (on page 141) include/bypass the built-in analog anti-alias filter age1439_input_alias_filter_get (on page 141) gets the anti-alias filter state age1439_input_autozero (on page 141) nulls out the input dc offset in baseband mode age1439_input_coupling (on page 141) selects ac or dc input coupling age1439_input_coupling_get (on page 141) get the input coupling type age1439_input_offset (on page 135) sets the dc offset settings for the current range age1439_input_offset_get (on page 135) gets the dc offset settings age1439_input_offset_save (on page 136) saves the dc offset settings in NVRAM age1439_input_range (on page 141) sets the full scale input range age1439_input_range_auto (on page 137) performs auto-ranging age1439_input_range_convert (on page 138) converts input range to volts age1439_input_range_get (on page 141) gets the input range age1439_input_signal_path (on page 141) selects baseband or IF signal path age1439_input_signal_path_get (on page 141) gets the signal path state age1439_input_signal (on page 141) connect/disconnect the input signal to the input ampli-

fier

age1439_input_signal_get (on page 141) gets the input buffer amplifier state age1439_state_save (on page 175) saves the current module state age1439_state_recall (on page 174) recalls a previous module state

Data format

age1439_data_setup (on page 90) sets all format and data output flow parameters age1439_data_blocksize (on page 90) determines the size of the output data block age1439_data_blocksize_get (on page 90) gets the output data block size age1439_data_delay (on page 90) determines FIFO delay in continuous mode age1439_data_delay_get (on page 90) gets FIFO delay age1439_data_memsize_get (on page 88) returns module's memory size age1439_data_mode (on page 90) selects block mode or continuous mode age1439_data_mode_get (on page 90) gets the data mode

age1439_data_port (on page 90) selects VME bus, local bus or fiber interface for output transmission

age1439_data_port_get (on page 90) gets the output port designation age1439_data_resolution (on page 90) selects 12 or 24 bits data resolution age1439_data_resolution_get (on page 90) gets the data resolution age1439_data_scale_get (on page 89) gets the data scale factor used to convert raw data to

volts

age1439_data_type (on page 90) selects real or complex output data age1439_data_type_get (on page 90) gets output data type age1439_data_spectral_order specifies the spectral order of the output data. age1439_data_spectral_order_get gets the spectral order of the output data. age1439_data_xfersize (on page 96) allows a specified amount of data to be read before an

entire block has been acquired. age1439_data_xfersize_get (on page 96) gets the data transfer size

61

Page 71
Image 71
Agilent Technologies E1439 manual Initializing and closing