Agilent E1439 Programmer's Reference

Functions listed alphabetically

age1439_vcxo

Selects whether the internal clock source in the module is turned on or off. This description also includes the query function:

age1439_vcxo_get

VXIplug&play Syntax

#include "age1439".h

ViStatus age1439_vcxo(ViSession id, ViInt16 vcxoState);

ViStatus age1439_vcxo_get(ViSession id, ViPInt16 vcxoStatePtr);

This command should be used only for specialized custom clock requirements. Most useful clock setups can be supplied by age1439_clock_setup.

Description

This function selects whether the internal clock source is turned on or off.

This function is ignored in IF path since the Agilent E1439D does not run in IF mode if the VCXO is turned off. If you switch from baseband to IF path the VCXO turns on; it remains on if you switch back to baseband.

Parameters

is the VXI instrument session pointer returned by the age1439_init function.

AGE1439_VCXO_OFF specifies that the internal clock source is turned off.

AGE1439_VCXO_ON that the internal source is turned on.

Returns a pointer to the actual state of the VCXO.

Return Value

AGE1439_SUCCESS indicates that a function was successful.

Values other than AGE1439_SUCCESS indicate an error condition or other important status condition. To determine the error message, pass the return value to “age1439_error_message” on page 102.

See Also

“Commands which halt active measurements” on page 198, “Default values” on page 201, “age1439_init” on page 132, “age1439_clock_setup” on page 78, “Using clock and sync” in chapter 3