Agilent E1439 Programmer's Reference

Functions listed by functional group

age1439_lbus_mode (on page 148) −sets the transmission mode of the local bus age1439_lbus_mode_get (on page 148) −gets the local bus transmission mode age1439_lbus_reset (on page 150) −resets the local bus age1439_lbus_reset_get (on page 150) −gets the local bus reset state

Debugging

age1439_cal_get (on page 75) −gets last calibration date of specified board

age1439_clock_recover (on page 77) −allows recovery from an out-of-spec external sample clock

age1439_driver_debug_level (on page 97) −sets the debug level age1439_driver_debug_level_get (on page 97) −gets the debug level age1439_error_message (on page 102) −returns error information obtained from function

calls

age1439_error_query (on page 103) −queries the module for the most recent error age1439_status_get (on page 176) −retrieves the module's status register information age1439_meas_status_get (on page 156) - retrieves the current measurement status register

information

age1439_self_test (on page 170) −performs a self-test on the module and returns the result

Digital processing

age1439_combo_setup (on page 87) −a quick way to set blocksize, center frequency, and sig- nal bandwidth with one function

age1439_filter_setup (on page 120) −sets the digital filter bandwidth and decimation filter parameters

age1439_filter_bw (on page 120) −selects a signal filter bandwidth age1439_filter_bw_get (on page 120) −gets the signal filter bandwidth age1439_filter_decimate (on page 120) −enables/disables an extra factor of 2 decimation age1439_filter_decimate_get (on page 120) −gets current state of extra decimation age1439_filter_sync (on page 123) −synchronizes the decimation filter counter age1439_frequency_setup (on page 128) −sets all zoom center frequency parameters age1439_frequency_center (on page 128) −sets the center frequency age1439_frequency_center_get (on page 128) −gets the current center frequency age1439_frequency_center_raw (on page 125) −quickly sets the center frequency age1439_frequency_center_raw_compute (on page 127) −quickly calculates the values for

age1439_frequency_center_raw age1439_frequency_center_raw_get (on page 125) −gets the raw center frequency

age1439_frequency_cmplxdc (on page 128) −selects a complex baseband measurement age1439_frequency_cmplxdc_get (on page 128) −gets the state of the baseband measurement

mode

age1439_frequency_sync (on page 128) −prepares the module for a synchronous frequency change

age1439_frequency_sync_get (on page 128) −gets the state of the synchronous change mode

Fiber Interface

age1439_fiber_BOF (on page 112) −controls whether or not automatically generated BOF events are transmitted

age1439_fiber_BOF_get (on page 112) −returns the current value of bofEnable age1439_fiber_clear (on page 106) −clears all data from the fiber interface FIFO buffers age1439_fiber_crc (on page 112) sets up the fiber interface to transmit and receive cyclic

62

Page 72
Image 72
Agilent Technologies E1439 manual Debugging