Chapter 19: RMON
256
Falling Threshold: This parameter specifies a specific value or
threshold level of the monitored statistic. When the value of the
monitored statistic becomes less than this threshold level, an alarm
event is triggered. The parameter’s range is 1 to 2147483647.
Rising Event Index: This parameter specifies the event index for the
rising threshold. Its range is 1 to 65535. This field is mandatory and
must match an Event Index that you previously entered in “Events” on
page 252.
Falling Event Index: This parameter specifies the event index for the
falling threshold. Its range is 1 to 65535. This field is mandatory and
must match an Event Index that you previously entered in “Events” on
page 252.
Owner: This parameter is used to identify the person who created an
entry. It is primarily intended for switches that are managed by more
than one person, and is an optional field.
4. Once you have configured the parameters, click Apply.
Your entry appears in the table at the bottom of the page. See Figure
104.
Figure 104. RMON Alarm Configuration Example Page (To be provided)
5. If you want to configure additional RMON alarms, repeat
steps 3 and 4.
6. From the main menu on the left side of the page, select Save
Configuration to Flash to permanently save your changes.