Chapter 2: Installation
68
Installing the AT-SBx31CFC Fabric Control Card
Perform the following procedure to install the AT-SBx31CFC Card:
Caution
The AT-SBx31CFC Card contains active electronic devices, which
can be damaged by electro-static discharges (ESD). Follow the
procedure given in “Protection Against Electrostatic Discharge
(ESD)” on page 60 to guard against ESD damage when unpacking
and installing this card.
1. Choose a slot in the chassis for the AT-SBx31CFC Fabric Control
Card. It can be installed in either slot 4 or 5.
2. Remove all components from the shipping package.
Note
Store the packaging material in a safe location. You may use the
original shipping material if you need to return the unit to Allied
Telesis.
3. Ensure that the following components are included in your package.
One AT-SBx31CFC Management Fabric Card
One RJ45 to DB9 management cable
If either item is missing or damaged, contact your Allied Telesis sales
representative for assistance.
4. Move the locking handles on the front panel to the open position as
shown in Figure 40.
Figure 40. Opening the Locking Handles of the AT-SBx31CFC Fabric
Control Card
1822
SBx31CFC
RESET
SD
CONSOLE
10/100/1000Base-T
1000 LINKACT
10/100 LINKACT
M/S
PSU
FAN
SBx STATUS
1
3
5
7
9
11
0
2
4
6
8
10
L/A
CFC
RS-232
READY BUSYFAULT
M/S
PSU
FAN
MASTER
SLAVE
NORMAL
FAULT
NORMAL
FAULT
NET MGMT
SYS STATUS