Switched Rack PDU

USER’S GUIDE

®

The Upload Event and Error Messages

The event and its error messages

The following system event occurs when the receiving Switched Rack PDU completes using the .ini file to update its settings.

Configuration file upload complete, with number valid values

This event has no default severity level.

If a keyword, section name, or value is invalid, the event text is extended to include notification of the following errors.

The export to and the subsequent upload by the receiving Rack PDU succeeds even if there are errors.

Event text

Description

 

 

Configuration file warning: Invalid

A line with an invalid keyword or value is ignored.

keyword on line number.

 

Configuration file warning: Invalid

 

value on line number.

 

 

 

Configuration file warning: Invalid

If a section name is invalid, all keyword/value pairs

section on line number.

in that section are ignored.

 

 

Configuration file warning:

A keyword entered at the beginning of the file (i.e.,

Keyword found outside of a

before any section headings) is ignored.

section on line number.

 

 

 

Configuration file warning:

If the file is too large, the Rack PDU stores and

Configuration file exceeds

processes what it can, but ignores what it cannot.

maximum size.

Reduce the size of the file, or divide it into two files,

 

and try uploading again.

 

 