3. | Connect known good optical | Yes | Go to step 4. |
|
| drive to interconnect board. |
|
|
|
| Verify that known good optical |
|
|
|
| No | Suspect interconnect board. |
| |
| drive is listed in the System |
| ||
| Profiler device tree. |
| Go to step 7 |
|
|
|
|
|
|
4. | With known good optical drive | Yes | Known good optical drive | J03 |
| installed, test for media inject/ |
| resolved inject/eject issue. | (J06) |
| eject. Verify drive accepts and |
| Replace optical drive. | |
| ejects known good media. |
|
|
|
| No | Go to step 7 |
| |
|
|
| ||
|
|
|
|
|
5. | Inspect optical drive slot during | Yes | Go to step 6 |
|
| disc insert/ eject. Verify that |
|
|
|
| No | Replace damaged optical | J03 | |
| discs can be inserted easily. | |||
|
|
| drive.. | (J06) |
|
|
|
|
|
6. | With known good optical | Yes | Media issue. No repair |
|
| media (Install disc), test for |
| necessary. Suggest user |
|
| media inject/eject. Does drive |
| investigate use of different |
|
| accept and eject known good |
| media. |
|
| media? |
|
|
|
| No | Go to step 3 |
| |
|
|
| ||
|
|
|
|
|
7. | Replace interconnect board | Yes | Issue resolved. Interconnect | X03 |
| with known good optical |
| board damaged |
|
| media (Install disc), test for |
|
|
|
| No | Interconnect board verified | M19 | |
| media inject/eject. Does drive | |||
| accept and eject known good |
| or replaced, and optical drive |
|
| media? |
| verified or replaced. Replace |
|
|
|
| logic board and retest. |
|
|
|
|
|
|
Mac mini (Late 2009) Symptom Charts — Mass Storage 56 |