Accessories

switching knob

allen screws

block

Universal Viewfinder UV-1

When using anamorphic lenses, the UV-1 allows desqueezed viewing of the ground glass image. This viewfinder arm can also be switched over to check the anamorphically squeezed image.

To switch over the viewfinder image, turn the switching knob photo. The knob does not need to be unlocked.

All other operating elements are identical in function to those on the standard viewfinder. The anamorphic viewfinder can also be used together with the 235 finder extender.

Adjusting the UV-1

Unlike the standard viewfinder, the anamorphic viewfinder will only provide an undistorted image in horizontal, locked position. The locking stops of the UV-1 can be adjusted to an exactly horizontal position.

Loosen (do not remove) the two allen screws photo in the locking stop.

Move the block photo until the viewfinder image is free of distortion.

Retighten the allen screws.

136