Hang the hook of the measurement device photo on the film core which is to be measured.

Attach the open magazine to the camera.

Do not place your hand in the running magazine!

To set the take-up shaft, run the camera at 24 fps. The tension measurement device should be showing ring “5”.

If the tension measurement device is not showing “5”, stop the camera.

Switch off the camera’s main switch and disconnect the camera from the power supply.

Place the special key photo in the holes of the friction adjustment and turn in steps. The adjustment must lock in at each step. When setting friction, the corresponding winding shaft must be held firmly.

Turn clockwise to increase friction, counter-clockwise to decrease friction.

Connect the camera to the power supply and switch on.

Run the camera at 24 fps.

Check the tension.

Note:

Repeat this procedure until ring “5” is shown.

After setting the friction, replace the tensioning plate.

Fasten the plate with the three screws.

core adapter

roller arm

measurement device

 

hook

 

 

 

 

special key

screws

transparent tensioning plate

Maintenance

153