Check all settings on the connected monitor.

If the mechanical iris is closed more than necessary, the IVS will compensate by increasing the gain and improve the image brightness electronically. This creates additional electronic noise. To avoid this, open the mechanical iris.

• To change the iris, turn the wheel with the iris symbol Õ.

10.3.3Alignment of the image position (X-, Y- and Rotation) and focus

The position of the image on the CCD-Chip and its focus can vary slightly from camera to camera. The video image on the monitor may appear not centered, rotated or out of focus.

All settings can be made by using a 1,5 mm allen key, which is delivered with the IVS.

Do not use force!

Image position adjustments in x- and y- direction can be made with the marked x- and y- screws photo.

The screw, marked with Ò moves the video image on the monitor horizontally. The screw, marked with Ó vertically.

Òalignment

Ó alignment

Note:

Due to design restrictions in size, the axis might

 

be not precisely in x- and y- direction

Image rotation can be changed on the screw, marked with the Ô-Symbol photo (page 80).

Focus can be changes, using the screw, which is marked with the F Symbol photo (page 80).

Video-Assist-System

81