•Swing the roller arm ➪ photo away from the winding shaft until it locks in place.
•Place the film roll next to the magazine, preferably on a film can.
•Insert the film through the upper slit on the magazine throat assembly from the inside ➪ photo.
Do not catch the film.
•With your free hand, turn the drive gear counter- clockwise while carefully pushing the film through until both perforation holes are picked up simultaneously by the sprockets.
•Keep turning the gear until the film has been transported through the throat assembly.
•Flip up the hinged locking clip on the feed shaft ➪ photo.
•Place the film roll on the feed shaft, ensuring that the feed shaft catch engages the slot on the plastic core.
•Press down the hinged locking clip on the feed shaft.
•By turning the drive gear
Ensure that the film is lying flat against the outside of the magazine housing.
•Without changing the length, thread the film into the right film channel. Do not catch the film.
Magazines
roller arm
magazine throat assembly
hinged locking grips
loop length marking
31