A trigger delay module manages the signals used for triggering envelopes and sequencer. There are 2 delays, which can function independently, in series or parallel following the setting on the “mode” selector.
Set to the “off” position, the 2 delays are independent. When their trigger input moves to an active state, their internal counter is initialized. The output will move to an active state when their internal counter reaches the value specified by the rotating “time” button. When the trigger input returns to an inactive state, the output immediately goes not an inactive state.
Set to the “parallel” position, the 2 internal counters start at the same time when the trigger input of the first delay goes to an active state. Each manages its output in function with its time setting.
In the series position, the second counter only begins when the output of the first delay moves to an active state.
Independent mode
Parallel mode
82 | ARTURIA – MOOG MODULAR V 2.6 – USER’S MANUAL |