Setting Up Out-of-Band Links

Recommended Method

The recommended method for connecting for out-of-band man- agement is with the AMS Link Extender included with your AsantéBridge 1012.

1

Connect the RJ45 connector on the AMS Link Extender to

the AMS Link Port on the rear panel of the AsantéBridge

 

1012 as shown in Figure 2-11.You can use either port.

 

Hub DIP Switch

 

2A/250V Slow Blow Fuse

 

Replace Only With Fuse of Same Rating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RJ21

10 BASE-T PORTS

IN or OUT

BNC

AUI

3-IN-1 UPLINK

 

 

THROUGH

RS232

AMS LINK

END

PARTITION

UP=PC

Spare Fuse in Fuse Holder

DOWN=TERMINAL

TRAFFIC

 

 

OR

RJ45

 

RS232

To PC COM Port

RJ45

DIN-8

Extender

To MAC Modem

Port

 

Figure 2-11 Connecting the AMS Link Extender

2

Connect the other end of the AMS Link Extender cable to

the COM port on your PC or the modem port on a Macin-

 

tosh.

3

Now locate the Hub DIP Switches on the AsantéBridge

rear panel and set both of the switches DOWN.

4

Push the Reset button on the front panel.

You are now ready to log in with AsantéView Out-of-Band.

Distance Restrictions

The total distance between the Asanté Management Station and the farthest hub in the chain cannot exceed 2000 feet, as mea- sured from the Asanté Management Station to the farthest hub.