Asante Technologies 1012 manual Resetting the Bridge

Models: 1012

1 110
Download 110 pages 37.51 Kb
Page 92
Image 92

Chapter 3 — AsantéBridge 1012 Local Management

Resetting the Bridge

You can reset the AsantéBridge 1012 in three different ways:

 

Cycle the power.This resets both the bridge and hub

 

portions of the device.The repeater is not affected.

 

Push the Reset button on the front panel.This resets

 

both hub and bridge.

 

Send the Reset system command from the Configura-

 

tion Menu.This resets both the bridge and the hub.

Figure 3-21 Resetting the Bridge

1

2

Use the arrow keys to select the Reset system command.

Press return to reset the bridge.

Confirmation is required.The command executes only after you have confirmed your choice.

Your display will begin to cycle through the bridge power- on diagnostics and return to the Local Management Menu.

3 Enter control-z to return to the Local Management Menu.

Remember that a reset:

Resets the bridge and hub statistics counters to zero

Erases any packets in bridge and hub memory at the time of the reset

Prevents the bridge from forwarding or filtering data flow until the power-on diagnostics have run to comple- tion and the bridge has completed reconfiguring

Erases dynamic forwarding addresses