Dual Trunk E1 Router

Table 11-1 Unit Problems (4 of 4)

Symptom

Probable Cause

Solution

 

 

 

Some invalid data is received mixed in with a mostly good menu display.

Refresh screen image.

1 or more units are missing at ID, or two units have the same ID.

To refresh screen, press

Ctrl-L.

Reduce the baud rate on the units and terminal if you are using the maximum (38400 baud) for communicating with a very large number of units.

If the cable from the network to the terminal exceeds the 15 m (50 ft.) maximum, fix the length.

Verify that none of the units are missing an ID and that no two units have the same unit ID.

NETWORK PROBLEMS

Table 11-2 Network Problems (1 of 4)

Symptom

Probable Cause

Solution

The unit experiences a loss of

• Equipment Failure

• Test E1.

signal or a loss of frame on the

 

• Apply hardware loop to front of

Network Port.

 

 

unit.

 

 

 

 

 

90

SALES: 0870 90 10 750

Dual Trunk E1 Router User’s Guide

Page 102
Image 102
Black Box LRU4240 manual Network Problems, Ctrl-L