Parameter

Description

 

 

Protocol Error - Number of PPP/MLPPP protocol errors detected in this port.

 

 

 

 

Table D-34 Menu-6B Multilink Frame Relay Port Configuration and Status

 

 

 

 

Paramete

 

 

r

Description

Default

 

 

 

Port 1/2

Include In Bundle - Yes, No

Yes

 

 

 

 

Status - Normal, Idle, Down, Remote Not Configured, Inconsistent Bundle,

(status)

 

Unknown Vendor, Loopback Detected, Test Active, Remote Link Up, and Awaiting

 

 

Remote Link

 

 

 

 

 

Protocol Errors - number of MFR protocol errors detected on the port

(counter)

 

 

 

Local

Local Bundle Identifier - (status) local identifier for logical T1 bundle

(ID no.)

 

 

 

 

Remote Bundle Identifier - (status) remote identifier for logical T1 bundle

(ID no.)

 

 

 

Table D-35 Menu-7 Feature Keys

Parameter

 

Default

 

RMON – PPP and Frame Relay RMON1 statistics

Capable

 

 

 

 

Service Level Agreement (Frame Relay SLA FRF.13)

Capable

 

 

 

RMON 2 - Protocols and application monitoring

Capable

 

 

 

 

Access Router 2 Ports

 

Capable

 

 

 

 

Access Router single port

 

Not capable

 

 

 

 

Dynamic Routing --

 

Capable

 

 

 

 

 

Table D-36 Alarm Configuration

 

 

 

 

 

 

 

 

Primary

Parameter—Options;

 

 

 

Parameters

Definition

Default

 

 

 

 

 

NET Alarms

Block All Alarms—Yes, No

No

 

 

Yes—Blocks the reporting of all alarms.

 

 

 

 

No—Enables the unit to report alarms.

 

 

 

 

 

 

 

 

Carrier Loss Alarm—Enabled, Disabled

Enabled

 

 

Enabled—The unit generates an alarm when a network carrier Loss of

Signal is detected on the network.

Disabled—Disables the alarm.

Sync Loss Alarm—Enabled, Disabled

Enabled—The unit generates an alarm when loss-of-frame is detected on Enabled the network.

Disabled—Disables the alarm.