Dual Trunk E1 Router

Table D-9

Menu-1 Unit Status (2 of 2)

 

 

 

Indication

 

Description

 

 

 

Send QRW (port, fraction)

 

Unit is sending QRW code.

 

 

 

Send All 1s (port, fraction)

 

Unit is sending all ones signal.

 

 

 

Send all 0s (port, fraction)

 

Unit is sending all zeros signal.

 

 

LP UP Remote (port, fraction)

Unit is sending loopdown code to remote site for 15 seconds.

 

 

LP DN Remote (port, fraction)

Unit is sending loopup code to remote site for 15 seconds.

 

 

 

No clock

 

Main clock source has failed.

 

 

 

Lamp Test

 

Unit is undergoing Lamp Test.

 

Table D-10 Menu-1 Network Status

 

 

Indication

Description

 

 

Normal Operation

No abnormal conditions exist.

 

 

Loss of Signal

Network signal is missing.

 

 

Loss of Frame

Network frame is missing.

 

 

AIS Alarm Received

AIS/keep alive.

 

 

RAI Alarm Received

Unit has received RAI

 

 

Set Code Received

Unit has received set code.

 

 

Reset Code Received

Unit has received reset code.

 

 

Excessive CRC Errors

Unit has exceeded BPV threshold.

 

 

Excessive OOF Errors

Unit has exceeded OOF threshold.

 

 

 

Table D-11 Menu-3A Carrier Reports and 3B User Reports

 

Event

 

 

Default

 

 

Unavailable Signal State - In ESF mode, this state is declared at the onset of ten consecutive

 

No

 

 

SESs.

 

 

 

 

 

 

 

 

 

 

Current Interval Timer - Displays the amount to time in a current interval, 0 - 899 seconds.

 

0

 

 

 

 

 

 

Errored Seconds (ES) - In ESF framing, a second with one or more ESF frame errors or CRC-

0

 

 

6 errors.

 

 

 

 

 

 

 

 

 

Unavailable Seconds (UAS) - In ESF mode, the number of seconds elapsed after 10 consecutive

0

 

 

SES events are received.

 

 

 

 

 

 

 

 

 

Severely Errored Seconds (SES) - In ESF mode, a second during which 320 or more CRC-6

 

0

 

 

violations or OOF events have occurred.

 

 

 

 

 

 

 

 

Bursty Errored Seconds (BES) - In ESF mode, a second with two CRC-6 errors to 320 CRC-6

0

 

 

errors.

 

 

 

 

 

 

 

 

 

 

Background Block Error (BBE) -

 

 

 

 

 

 

 

 

118

SALES: 0118 965 5100

Dual Trunk E1 Router User’s Guide

Page 130
Image 130
Black Box LRU4240 manual Event Default, Background Block Error BBE 118 Sales 0118 965