Dual Trunk E1 Router

Table D-5 Menu-0E Performance Monitoring Configuration

 

 

Parameter

Parameter - Options; Definition

 

 

Status

Active - Passing data through the Permanent Virtual Circuit (PVC)

 

Inactive - PVC is broken

 

Deleted - PVC is not available

 

Table D-6 Menu-0F LMI Configuration

 

 

Parameter

Parameter- Options; Definition

 

 

Enable

Enable or disable LMI

 

 

Type

Select between Annex A, Annex D, and LMI revision 1.

 

Default: Annex D

 

 

Enquiry Tx Timer

Sets the interval between STATUS ENQUIRY messages. Set the value between 5 and

 

30 seconds, in increments of 5.

 

Default: 10 seconds

 

 

Full status count

Sets the number of polling cycles for Link Verification before the unit generates the

 

Full Status request. Set the count to an integer between 1 and 255

 

 

Max Lmi Error

The number of errors that can occur on the LMI link before the reporting that the

 

interface is down.

 

 

Enquiry Rx Timer

Sets the number of seconds between the sending of a STATUS ENQUIRY and the

 

reception of the response. Set this value to an integer between 5 and 30, in increments

 

of 5.

 

Default: 15 seconds

 

 

Unit Location

Select UNI-U or UNI-N.

 

Table D-7 Menu-0H SLA Configuration

 

 

Parameter

Description

 

 

Enable -

Set this field to Enabled to collect SLA data

 

Default: Disabled

 

 

FDR/DDR Sample

Set the sampling period between 1 minute and 255 minutes. The time period represents

Period

the time interval between requests to the far end of the PVC.

 

Default: 1

 

 

FDR Threshold

Set this threshold between 0% and 100%. 0% means this feature is disabled.

Configurable to one thousandth of a percent (for example, 99.999%). When the FDR falls below this threshold:

• An event is sent to the Event Log

• A trap will be sent to the NMS (if configured)

• An alarm message will be displayed on the Terminal User Interface

• An FDR threshold violation is counted0% Default: 0%