Dual Trunk E1 Router

 

Field

Definition — Options

Default

 

 

Pattern Error Counter

The number of pattern errors occurring during the current

0

 

 

 

test. This will only display when Pattern Test reads

 

 

 

 

Locked Seconds or Relocked Seconds.

 

 

 

 

 

 

 

 

CRC (or CRC4) Errors

The number of CRC (or CRC4) errors occurring during the

0

 

 

 

current test.

 

 

 

 

 

 

 

 

Code Violations

The number of Code Violations occurring during the

0

 

 

 

current test.

 

 

 

 

 

 

 

 

Out of Frame Event

Indicates 2 bits out of 4 bits framing errors for both ESF

0

 

 

 

and D4 modes

 

 

 

 

 

 

 

 

Frame Error Event

Indicates 2 bits out of 4 bits framing errors

0

 

 

 

 

 

 

 

Last Self Test Result

The result of the last test performed. Read only.

0 (if no self-test

 

 

 

Options:

has been

 

 

 

Self Test Passed

performed)

 

 

 

Error nn (0 to 5)

 

 

 

 

 

 

 

 

Next Test (port, fraction)

The next test to run is set in this field. Options:

Self Test

 

 

 

1. Self Test†

 

 

 

 

3. Loop NET

 

 

 

 

4. Loop Payload*

 

 

 

 

5. Loop Up Remote *

 

 

 

 

6. Loop Down Remote*

 

 

 

 

7. QRW Pattern*

 

 

 

 

8. 1:7 Pattern*

 

 

 

 

9. 3:24 Pattern*

 

 

 

 

10. 1:1 Pattern*

 

 

 

 

11. All 1s Pattern*

 

 

 

 

12. All 0s Pattern*

 

 

 

 

13. 1:2 Pattern*

 

 

 

 

14. 1:4 Pattern*

 

 

 

 

15. User 1 Pattern*

 

 

 

 

16. User 2 Pattern*

 

 

 

 

17. Smart Jack Set‡

 

 

 

 

18. Smart Jack Reset‡

 

 

 

 

19. Lamp Test†

 

 

 

 

*All of these tests offer the option of selecting which

 

 

 

 

fraction of the T1/E1 signal the test applies to (NET1,

 

 

 

 

NET2). FULL applies to the entire T1/E1 signal

 

 

 

 

(including IDLE timeslots).

 

 

 

 

 

 

 

 

Next Test Length

The length of the next test is set in this field.

Unlimited

 

 

 

15 min., 1 min., 60 min., Unlimited

 

 

 

 

With the Self Test, Loop Up Remote and Loop Down

 

 

 

 

Remote, this parameter does not apply.

 

 

 

 

 

 

 

 

Full Bandwidth Loop Code

The Loop code to use in the next test is set in this field.

Standard

 

 

 

Options: Standard, Alternate, Disabled

 

 

 

 

 

 

 

 

Fractional Loop Code

The Loop code to use in the next test is set in this field.

Standard

 

 

 

Options: Standard, Alternate, Disabled, and ITU-T V.54

 

 

 

 

 

 

Dual Trunk E1 Router User’s Guide

TECHNICAL: 0118 931 2233

131

Page 143
Image 143
Black Box LRU4240 manual Pattern Error Counter, CRC or CRC4 Errors, Code Violations, Out of Frame Event, Frame Error Event