138
PRO SWITCHING SYSTEM
Solution #3:Make sure the power supply modules and the control card are
functioning properly.
Problem:Individual lines cannot be switched.
Solution #1:Make sure that the interface card is fully inserted into the rack mount.
Solution #2:Make sure that the power supply modules are functioning properly.
8.4 PC Control Problems
Problem:The Pro Switching System does not communicate with the controlling PC.
Solution #1:Make sure that DS5, the configuration DIP switch, is set properly. The
baud rate selected with DS5 must match the baud rate defined for the
communication port that the Pro Switching System is connected to.
Solution #2:Make sure that the rack address (DS4) and the password DIP switch
(DS3) match your site map.
Solution #3:Make sure that the Pro Switching System is connected to the
controlling PC, with a correctly configured communication cable.
Solution #4:Make sure that the communication cable is connected to the same
communication port as defined in your site map.
Solution #5:Make sure that the communication port defined in your site map is
enabled.