186
PRO SWITCHING SYSTEM
Variable: 1.3.6.1.4.1.509.1.7.1.8.[sigAlarmIndex]
where [sigAlarmIndex] is a number (from 1 to
32) of an alarm definition to which the start
time entry is assigned.
Example: Set the alarm definition to become active on
Monday at 13:30 (1:30 pm) for alarm index 1.
Operation: Set
Variable: 1.3.6.1.4.1.509.1.7.1.8.1
Set Value: MON 13:30
sigAlarmStop
Description: The stop time when the alarm definition is not
active (for example, FRI 17:45). You can SET
and GET the value of this variable.
Parameters: Day: MON, TUE, WED, THU, FRI, SAT,
SUN
Time: 00:00 to 23:59
MIB Path: 1.3.6.1.4.1.509.1.7.1.9
iso(1).org(3).dod(6).internet(1).private(4).ent
erprises(1).Hadax(509).
IntelliSwitch2000(1).sigAlarmTable(7).sigAlar
mEntry(1).sigAlarmStop(9)
Variable: 1.3.6.1.4.1.509.1.7.1.9.[sigAlarmIndex]
where [sigAlarmIndex] is a number (from 1 to
32) of an alarm definition to which the stop
time entry is assigned.
Example: Set the alarm definition to become inactive on
Friday at 17:45 (5:45 pm) for alarm index 1.
Operation: Set
Variable: 1.3.6.1.4.1.509.1.7.1.9.1
Set Value: FRI 17:45
sigAlarmState
Description: The current status of the alarm. You can only
GET the value of this variable.