194
PRO SWITCHING SYSTEM
Parameters: Day: MON, TUE, WED, THU, FRI, SAT, SUN
Time: 00:00 to 23:59
MIB Path: 1.3.6.1.4.1.509.1.9.1.2
iso(1).org(3).dod(6).internet(1).private(4).ent
erprises(1).Hadax(509).
IntelliSwitch2000(1).timeTrigOpTable(9).time
TrigOpEntry(1).
timeTrigOpTime(2)
Variable: 1.3.6.1.4.1.509.1.9.1.2.[timeTrigOpIndex]
where [timeTrigOpIndex] is a number (from 1
to 32) of a time-triggered switching operation
to which the time entry is assigned.
Example: Set the switching time of time-triggered
operation 4 to Tuesday at 5 pm (17:00).
Operation: Set
Variable: 1.3.6.1.4.1.509.1.9.1.2.4
Set Value: TUE 17:00
timeTrigOpFreq
Description: Indicates how often the switching operation
shall be performed. Note that operations set to
‘once(1)’—one-time switching—are
automatically destroyed when they have been
executed. You can SET and GET the value of
this variable.
Parameters: never(0), once(1), every_week(2),
every_day(3)
MIB Path: 1.3.6.1.4.1.509.1.9.1.3
iso(1).org(3).dod(6).internet(1).private(4).ent
erprises(1).Hadax(509).
IntelliSwitch2000(1).timeTrigOpTable(9).time
TrigOpEntry(1).
timeTrigOpFreq(3)