PRO SWITCHING SYSTEM
Example: Process all variables for time-triggered
operation 1 and make this row active. You can
SET and GET the value of this variable.
Operation: Set
Variable: 1.3.6.1.4.1.509.1.9.1.10.1
Set Value: createAndGo(4)
D.11 Bus-Triggered Operations
The following variables allow you to perform bus-triggered switching operations for
your Pro Switching System unit. In general, all variables having a common
“busTrigOpIndex” (which you select) are part of the same bus-triggered operation.
Bus-triggered operations allow switching operations across several racks. The racks
connect to the inter-rack bus and broadcast a bus code when an alarm condition
occurs. Racks that have user-defined bus triggered operations programmed for
that code will perform the switching operation.
The inter-rack bus connects racks to each other through their COMM ports; the
COMM OUT port on one rack connects to the COMM IN port on another rack.
Use DB25F to DB25M cable, pin-to-pin (type 2 cable).
busTrigOpCode
Description: Bus code received over the inter-rack bus,
triggering the switching operation. You can
SET and GET the value of this variable.
Parameters: 1 to 127
MIB Path: 1.3.6.1.4.1.509.1.10.1.2
iso(1).org(3).dod(6).internet(1).private(4).ent
erprises(1).Hadax(509).
IntelliSwitch2000(1).busTrigOpTable(10).busT
rigOpEntry(1).
busTrigOpCode(2)
Variable: 1.3.6.1.4.1.509.1.10.1.2.[busTrigOpIndex]
where [busTrigOpIndex] is a number (from 1
to 32) of a bus-triggered switching operation to
which the bus code entry is assigned.