D.4 Gang SwitchingThe following variables allow you to perform gang switching operations for your
unit.
gangSwitchPush
Description: Setting this variable pushes the gang switch
button on the rack to perform group switching
on the line cards. Pushing the A(1), B(2), C(3),
or D(4) button forces all line cards to switch to
the A, B, C, or D port, respectively. Pushing the
N(5) button forces all line cards to switch to
their normal (user-defined) port. Pushing the
SET_N(6) button defines the current port of
each line card as its normal port. You can only
SET the value of this variable.
Parameters: Yes(1) to push the gang switch button.
MIB Path: 1.3.6.1.4.1.509.1.3.1.2
iso(1).org(3).dod(6).internet(1).private(4).ent
erprises(1).Hadax(509).
IntelliSwitch2000(1).gangSwitchTable(3).gang
SwitchEntry(1).
gangSwitchPush(2)
Variable: 1.3.6.1.4.1.509.1.3.1.2.[gangSwitchIndex]
where [gangSwitchIndex] is
1 for pushbutton A (port A)
2 for pushbutton B (port B)
3 for pushbutton C (port C)
4 for pushbutton D (port D)
5 for pushbutton N (normal)
6 for pushbutton SET N (set normal)
Example: Switch all line cards to port C.
Operation: Set
Variable: 1.3.6.1.4.1.509.1.3.1.2.3
Set Value: Yes(1)