202
PRO SWITCHING SYSTEM
MIB Path: 1.3.6.1.4.1.509.1.10.1.4
iso(1).org(3).dod(6).internet(1).private(4).ent
erprises(1).Hadax(509).
IntelliSwitch2000(1).busTrigOpTable(10).busT
rigOpEntry(1).
busTrigOpCardsList(4)
Variable: 1.3.6.1.4.1.509.1.10.1.4.[busTrigOpIndex]
where [busTrigOpIndex] is a number (from 1
to 32) of a bus-triggered switching operation to
which the list is assigned.
Example: Create a list from line cards 2, 5, 10, 12, 15, and
16 to switch for bus-triggered switching
operation 1.
Operation: Set
Variable: 1.3.6.1.4.1.509.1.10.1.4.1
Set Value: 2 5 10 12 15 16
busTrigOpComment
Description: User comment for each bus-triggered switching
operation. You can SET and GET the value of
this variable.
Parameters: Up to 31 characters
MIB Path: 1.3.6.1.4.1.509.1.10.1.5
iso(1).org(3).dod(6).internet(1).private(4).ent
erprises(1).Hadax(509).
IntelliSwitch2000(1).busTrigOpTable(10).busT
rigOpEntry(1).
busTrigOpComment(5)
Variable: 1.3.6.1.4.1.509.1.10.1.5.[busTrigOpIndex]
where [busTrigOpIndex] is a number (from 1
to 32) of a bus-triggered switching operation to
which the user comment is assigned.
Example: Enter a user comment for bus-triggered
switching operation 1.