183
APPENDIX D: Proprietary MIB
sigAlarmName
Description: The monitored signal of the alarm. You can
SET and GET the value of this variable.
Parameters: txd(1), rxd(2), dcd(3), cts(4), rts(5), dsr(6),
dtr(7), ri(8), tc(9), rc(10), ec(11), sqd(12),
rl(13), ll(14), dce(15), dte(16), tm(17),
ctr(18), ind(19), set(20), byt(21)
MIB Path: 1.3.6.1.4.1.509.1.7.1.4
iso(1).org(3).dod(6).internet(1).private(4).ent
erprises(1).Hadax(509).
IntelliSwitch2000(1).sigAlarmTable(7).sigAlar
mEntry(1).sigAlarmName(4)
Variable: 1.3.6.1.4.1.509.1.7.1.4.[sigAlarmIndex]
where [sigAlarmIndex] is a number (from 1 to
32) of an alarm definition to which the signal is
assigned.
Example: Set DCD as the monitored signal for alarm
index 1:
Operation: Set
Variable: 1.3.6.1.4.1.509.1.7.1.4.1
Set Value: DCD(3)
sigAlarmCondition
Description: The signal state that signifies an alarm
condition (for example, MARK). You can SET
and GET the value of this variable.
Parameters: mark(1), space(2), active(4), inactive(8)
MIB Path: 1.3.6.1.4.1.509.1.7.1.5
iso(1).org(3).dod(6).internet(1).private(4).ent
erprises(1).Hadax(509).
IntelliSwitch2000(1).sigAlarmTable(7).sigAlar
mEntry(1).
sigAlarmCondition(5)