196
PRO SWITCHING SYSTEM
timeTrigOpStop
Description: Time when an ‘every_day’ operation is
deactivated. The ‘every_day’ is set in the
‘timeTrigOpFreq’ variable. You can SET and
GET the value of this variable.
Parameters: Day: MON, TUE, WED, THU, FRI, SAT,
SUN (ignored)
Time: 00:00 to 23:59
MIB Path: 1.3.6.1.4.1.509.1.9.1.5
iso(1).org(3).dod(6).internet(1).private(4).ent
erprises(1).Hadax(509).
IntelliSwitch2000(1).timeTrigOpTable(9).time
TrigOpEntry(1).
timeTrigOpStop(5)
Variable: 1.3.6.1.4.1.509.1.9.1.5.[timeTrigOpIndex]
where [timeTrigOpIndex] is a number (from 1
to 32) of a time-triggered switching operation
to which the stop time is assigned.
Example: Set the stop time of the ‘every_day’ operation
to 6 pm (18:00) for time-triggered switching
operation 1.
Operation: Set
Variable: 1.3.6.1.4.1.509.1.9.1.5.1
Set Value: MON 18:00
timeTrigOpSwitchToPort
Description: Port switched to at the time of the switching
operation. You can SET and GET the value of
this variable.
Parameters: none(0), A(1), B(2), C(3), D(4), normal(5)
MIB Path: 1.3.6.1.4.1.509.1.9.1.6
iso(1).org(3).dod(6).internet(1).private(4).ent
erprises(1).Hadax(509).
IntelliSwitch2000(1).timeTrigOpTable(9).time
TrigOpEntry(1).
timeTrigOpSwitchToPort(6)