86
PRO SWITCHING SYSTEM
2. From the main menu, select Monitor, then Describe. The description screen
for the object appears.
3. Edit or add the appropriate information for the object.
Status Legend
Follow this procedure to display the status legend, which shows the states of the
objects using color codes. By default, they are:
Red (Critical): indicates the device is having serious problems, such as being
down.
Dark Red (Major): indicates a problem with some degradation of operation.
Orange (Minor): indicates a noncritical condition. There maybe some device
degradation.
Yellow (Warning): indicates a noncritical condition. No degradation has
occurred.
Mustard (Marginal): indicates that a device is approaching shutdown or
malfunction.
Magenta (Informational): indicates that an informational message about the
device has been sent by an application.
Cyan (Disabled): indicates the device is shut down.
Wheat (Unmanaged): indicates that the device is not managed by an HP
OpenView application.
Green (Normal): indicates the device is in a normal state. The device is up and
should be working properly.
Blue (Unknown): indicates the device application does not report its status, or
the map changed and the status has not been reported to HP OpenView for
Windows.
To Display the Status Legend
From the main menu, select Monitor, then Status Legend. The status legend
screen appears.