192
PRO SWITCHING SYSTEM
Example: Set code 50 to be emitted over the inter-rack
bus when the alarm(s) occur. Assign the code
to alarm-triggered switching operation 4. You
can SET and GET the value of this variable.
Operation: Set
Variable: 1.3.6.1.4.1.509.1.8.1.5.4
Set Value: 50
alarmTrigOpComment
Description: User comment for each alarm-triggered
switching operation. You can SET and GET the
value of this variable.
Parameters: Up to 31 characters
MIB Path: 1.3.6.1.4.1.509.1.8.1.6
iso(1).org(3).dod(6).internet(1).private(4).ent
erprises(1).Hadax(509).
IntelliSwitch2000(1).alarmTrigOpTable(8).alar
mTrigOpEntry(1).
alarmTrigOpComment(6)
Variable: 1.3.6.1.4.1.509.1.8.1.6.[alarmTrigOpIndex]
where [alarmTrigOpIndex] is a number (from
1 to 32) of an alarm-triggered operation to
which the user comment is assigned.
Example: Enter a user comment for alarm-triggered
switching operation 3.
Operation: Set
Variable: 1.3.6.1.4.1.509.1.8.1.6.3
Set Value: “Back up Toronto if CSU
fails”
alarmTrigOpRowStatus
Description: Selections for managing rows in the alarm-
triggered operations table. A row is an entry or
group of variables. Each row is identified by its
index— alarmTrigOpIndex—and contains
entries for determining switching operations.