204
PRO SWITCHING SYSTEM
D.12 TrapsThe following traps (messages) are generated by the rack when certain conditions
occur, as listed in each description below. All traps carry the
‘mibSystem.sysObjectId’ whose value is 1.3.6.1.4.1.509.1.
The generic traps are predefined standard traps that are applicable to most
devices. The specific traps are only particular to the Pro Switching System rack.
Note that you must configure the rack with an IP address to where the traps will be
sent, using the command SET RACK SNMP MANAGER. Refer to the Chapter 5 for
more information on configuring the rack.
D.12.1 G
ENERIC
T
RAPS
coldStart 0 The “Generic trap = 0” statement is a
standard trap that is sent when the rack
reinitializes. It carries the ‘mibSystem.sysDescr’
whose MIB path is 1.3.6.1.2.1.1.1.
D.12.2 S
PECIFIC
T
RAPS
powerStatusChange 1 This trap is generated when the value
of the ‘powerStatus’ variable changes. The trap
returns information on the ‘powerStatus’
variable as listed below. For more information
on the variable, see its listing presented earlier
in the chapter.
powerStatus—
Description: Status of the power supply.
Parameters: absent(0) Power supply is not installed
ok(1) Power supply is functioning
properly
fail(2) Power supply is installed but
not functioning
Variable: 1.3.6.1.4.1.509.1.2.1.2.[powerIndex]
where [powerIndex] is
1 for power supply 1
2 for power supply 2