www.axxessid.com

Installation & User Guide

Proximity Request to Exit

The Proximity REX detects the hand within the range of approximately 5cm. Once the hand has been detected, the relay goes off and closes the connection between the relay board and the request to exit terminal on the AX100 controller. The Proximity REX acts exactly like the REX Button and once the request to exit has been granted, the appropriate transaction appears on the main screen stating the time and the name of the access point. Please note that this product is based on infrared

technology; therefore other infrared light sources may affect the performance of this detector.

Technical Details

Power Requirement: 10-14 VDC (15mA Quiescent. 35mA Operated)

Changeover relay contacts rated 30VDC Max. 1A non-inductive.

The diagram below shows the connections between the proximity REX and the AX100 controller.

AX100 Proximity REX

CCOM

REX NO

AX200 Installation & User Guide – July 2007

1 1 8

Page 118
Image 118
Casio AX200 manual Proximity Request to Exit