Cisco Systems AIRPWRINJ15002 manual Connecting a DC Power Cable to the Access Point, 2-55

Models: AIRPWRINJ15002 AIRCAP1552EUAK9 AIRCAP1552EAK9RF

1 164
Download 164 pages 31.9 Kb
Page 101
Image 101
Connecting a DC Power Cable to the Access Point

Chapter 2 Installing the Access Point

Powering the Access Point

Step 3 Align the notch in the AC power cable connector with the key in the access point AC power connector, and push the cable connector into the access point connector (see Figure 2-39or Figure 2-40). When fully seated, rotate the cable connector ring clockwise until hand-tight.

Step 4 Ensure that the antennas are connected to the access point before you apply power to the access point. Step 5 Turn on the AC power at the designated circuits.

Connecting a DC Power Cable to the Access Point

When powering the access point with DC power, you must ensure that DC power can be conveniently removed from the unit. The power should not be removed by disconnecting the DC power connector on the unit.

Warning A readily accessible two-poled disconnect device must be incorporated in the fixed wiring. Statement 1022

Warning Connect the unit only to DC power source that complies with the safety extra-low voltage (SELV) requirements in IEC 60950 based safety standards. Statement 1033

To connect a DC power cable, you need to supply these tools and material:

Shielded outdoor-rated DC power cable (minimum 18 AWG) with outside cable diameter of 0.20 to 0.35 inch (0.51 to 0.89 cm).

Adjustable or open-end wrench

Small flat screw driver

Two-pin DC power connector (Cisco supplied)

To connect the DC power cable to the access point, follow these steps:

Step 1 Before connecting DC power to the access point, ensure that the ground is connected to the access point (see the “Grounding the Access Point” section on page 2-41.

Step 2 Turn off all power sources to the access point, including the DC power source.

Warning This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. Statement 1028

Caution When installing DC power to the access point, always connect the access point end of the cable FIRST. When removing the DC power connector, always disconnect the access point end of the cable LAST.

If your access point contains a backup battery pack, you must press the reset button for 10 seconds or more (see the “Disabling Backup Battery Power” section on page 3-10.)

Step 3 Use an adjustable wrench, a 22-mm socket, or a Sealcon S-2200 -WR wrench to remove the plug in the DC power connector opening (see Figure 2-41for the location of the DC power connector).

 

 

Cisco Aironet 1550 Series Outdoor Mesh Access Point Hardware Installation Guide

 

 

 

 

 

 

OL-24247-01

 

 

2-55

 

 

 

 

 

Page 101
Image 101
Cisco Systems AIRPWRINJ15002, AIRCAP1552EAK9RF, AIRCAP1552EUAK9 manual Connecting a DC Power Cable to the Access Point, 2-55