Chapter 2 Installing the Access Point

Powering the Access Point

Powering the Access Point

The access point can be powered by one of these methods:

PoE—56 VDC; for 1552E and 1552EU access points

Connecting a 1500 Series Power Injector, page 2-45

AC power

110 to 240 VAC for a 1552I access point—Connecting Streetlight AC Power, page 2-51

110 to 480 VAC for 1552E and 1552EU access points—Connecting Streetlight AC Power, page 2-51

120 VAC—Connecting an AC Power Cable to the Access Point, page 2-54

External 12 VDC

Connecting a DC Power Cable to the Access Point, page 2-55

POC—40 to 90 VAC (Quasi-AC); only for a 1552C and 1552CU access points

Connecting a Cable POC Power to the Access Point, page 2-58

Note In all cases above, the AC branch circuit powering the access point must be limited to no more than 20A from the over-protection device supplied by the user. This branch power protection must meet all local and national electrical codes.

Connecting a 1500 Series Power Injector

The power injector provides (AIR-PWRINJ1500-2=) 56 VDC to the access point over the Ethernet cable and supports a total end-to-end Ethernet cable length of 100 m (328 ft) from the switch to the access point.

Note The PoE-Out port is disabled when the access point is powered by the power injector.

Note When not using the AC input connector to power the 1552E or 1552EU (for example when powering using the Cisco power injector), it is important to cover the AC power entry connector. The correct cap is Remke part number 75-0086 (http://www.remke.com/).

When your access point is powered by an optional power injector, follow these steps to complete the installation:

Step 1 Before applying PoE to the access point, ensure that the access point is grounded (see the “Grounding the Access Point” section on page 2-41.

Step 2 Review Figure 2-2to identify the components needed for the installation.

Note The 1550 power injector can only be used in an indoor environment, therefore, the cable from the injector must travel from the protected location to the outside mounted access point.

 

 

Cisco Aironet 1550 Series Outdoor Mesh Access Point Hardware Installation Guide

 

 

 

 

 

 

OL-24247-01

 

 

2-45

 

 

 

 

 

Page 91