Cisco Systems AIRCAP1552EAK9RF manual 2-50, AC Power Cord, Cord Diameter, Comment, Description

Models: AIRPWRINJ15002 AIRCAP1552EUAK9 AIRCAP1552EAK9RF

1 164
Download 164 pages 31.9 Kb
Page 96
Image 96
AC Power Cord Information

Chapter 2 Installing the Access Point

Powering the Access Point

Table 2-4

AC Power Cord Information

 

 

 

 

AC Power Cord

Cord Diameter

Comment

 

 

 

AIR-CORD-R3P-40NA=

0.398 to 0.413 in.

The three prong plug is limited to 120 VAC.

 

 

(10.1 mm to 10.5 mm)

Internal wiring is rated at 600 VAC insulation

 

 

 

protection.

 

 

 

AIR-CORD-R3P-40UE=

0.398 to 0.413 in.(10.1 mm

Power cord rating is 100 to 480 VAC. Internal

 

 

to 10.5 mm)

wiring is 16 AWG.

 

 

 

AIR-PWR-ST-LT-TAP=

Strain relief bushing not

Power cord rating is 100 to 480 VAC

 

 

needed

 

 

 

 

 

When using a user-supplied AC power plug on the AIR-CORD-R3P-40UE= power cord, ensure that the plug is certified for outdoor use and that it has a minimum IP67 rating, such as Interpower 84131251 or Hubbell HBL316P6W (IEC/EN 60309) pin-and-sleeve type connectors. The European Union power cord plug pinouts are listed in Figure 2-37. For the location of the AC power connectors, see Figure 2-39and Figure 2-40.

Figure 2-37 European Union Plug Pinouts

1

32

255269

Pin

Description

Conductor Color

Pin

Description

Conductor Color

 

 

 

 

 

 

1

Ground

Green/Yellow

3

Neutral

Blue

 

 

 

 

 

 

2

Live

Brown

 

 

 

 

 

 

 

 

 

Caution All AC power plugs and AC receptacles must be protected from water and other outdoor elements. Use a UL listed waterproofing enclosure suitable for covering the AC receptacle and AC power plug that supplies power to the unit as described in Article 406 of the NEC. If the power cord goes through a metal cover, install a bushing to prevent fraying of the cord.

When using a strain relief bushing, you should follow these recommendations:

Use properly sized parts (see Table 2-4for the power cord diameter)

Use bushings that are safety certified

Use parts that are suitable for outdoor installation

Caution If your power cord does not use an AC power plug, you must ensure that the power source is OFF before connecting or disconnecting the power cord wires from the power source.

 