Chapter 2 Installing the Access Point

Mounting the Access Point

Tip When installing the 1552C or 1552CU access point using the pole mount kit, the grounding lug and cable must be attached to the access point before attaching the access point to the mounting bracket.

Step 3 Attach the grounding lug and cable to the access point. Refer to “Grounding the Access Point” section on page 2-41. See Figure 2-24.

Figure 2-24 Attaching Grounding Lug to Grounding Point

1

1

2

1581

33

 

 

Phillips head M4 x10mm screws (supplied

2

Grounding lug

with pole mount kit)

 

 

 

 

 

Step 4 Screw a M8 x16 bolt in the top support bolt hole on each side the access point (see Figure 2-22). Do not screw the bolt all the way in; leave approximately a 0.25 inch (0.635 cm) space.

 