Cisco Systems AIRCAP1552EUAK9, AIRCAP1552EAK9RF Before Beginning the Installation or Replacement

Models: AIRPWRINJ15002 AIRCAP1552EUAK9 AIRCAP1552EAK9RF

1 164
Download 164 pages 31.9 Kb
Page 124
Image 124
Before Beginning the Installation or Replacement

Chapter 4 Installing or Replacing the Backup Battery

Before Beginning the Installation or Replacement

Before Beginning the Installation or Replacement

The backup battery is located internal to the 1552E and 1552EU access points and attached to the radio cover. The backup battery cannot be installed or replaced in an outdoor environment. You must use a static-protected work surface within an indoor environment.

Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment.

Statement 1030

Caution ESD can damage the internal components of the access point. We recommend that the backup battery installation or replacement procedures be performed by an ESD-trained service technician at an ESD-protected workstation.

The following operations summarize the backup battery installation or replacement procedure:

1.If the access point has been deployed, deactivate all power sources, remove all cables, remove the access point.

2.Follow standard electrostatic discharge (ESD) procedures.

3.Place the access point on an indoor ESD-protected work surface.

4.Open the access point’s radio cover.

5.If applicable, remove the defective backup battery.

6.Install the new backup battery.

7.Connect the backup battery cable.

8.Close the access point radio cover.

9.Deploy your access point.

Cisco Aironet 1550 Series Outdoor Mesh Access Point Hardware Installation Guide

4-2

OL-24247-01

 

 

Page 124
Image 124
Cisco Systems AIRCAP1552EUAK9, AIRCAP1552EAK9RF, AIRPWRINJ15002 manual Before Beginning the Installation or Replacement