Figure 2-41 Location of the DC Power Liquid-Tight Adapter

Chapter 2 Installing the Access Point

Powering the Access Point

Figure 2-41 Location of the DC Power Liquid-Tight Adapter

12

255240

1

DC power connector with liquid-tight adapter

2

Ground lug screw holes

Step 4 Loosen the round end of the liquid-tight adapter by turning counterclockwise, but do not remove (see Figure 2-42).

Figure 2-42 Liquid-Tight Adapter

1

Thread end

2

Round end

Note The liquid-tight adapter accepts a cable diameter of 0.20 to 0.35 in. (0.51 to 0.89 cm).

Step 5 Insert a bare end of the DC power cable into the rounded end of the liquid-tight adapter (see Figure 2-42), and pull approximately 6 inches of cable through the adapter.

Step 6 Strip the DC cable jacket back about 1 inch to expose the wires and strip the insulation about 3/8 inch (9.5 mm) from each wire.

Step 7 Insert each wire into the two-position terminal strip (supplied), and tighten each wire using a 0.1 inch (0.25 cm) flat screw driver (see Figure 2-43).

 

Cisco Aironet 1550 Series Outdoor Mesh Access Point Hardware Installation Guide