Appendix A Technical Specifications

RP Port Specifications.

RP Port Specifications.

Table A-8

RP Port Specifications

 

 

 

Description

 

Value

 

 

 

Console port

 

EIA/TIA-232 RJ-45 interface, 115200 Baud, 8 data, no

 

 

parity, 1 stop bit with software handshake (default)

 

 

 

Auxiliary port

 

EIA/TIA-232 RJ-45 interface, 115200 Baud, 8 data, no

 

 

parity, 1 stop bit with software handshake (default)

 

 

Management ports (0, 1)

Triple-speed (10M/100M/1000M) RJ-45

 

 

Sync ports (0, 1)

Can be configured as one of the following:

 

 

BITS (Building Integrated Timing System) port

 

 

J.211 or UTI (Universal Timing Interface) port

 

 

 

Power Consumption Specifications

The following table lists the power consumption specifications for a fully configured chassis.

Caution Be sure that the chassis configuration complies with the required power budgets. Failure to properly verify the configuration may result in an unpredictable state if one of the power units fails. Contact your local sales representative for assistance.

Table A-9 Power Consumption Specifications

Description

Value

 

 

 

Power consumption

400

W at 77°F (25°C)

 

425

W at 104°F (40°C)

 

450

W at 131°F (55°C)

 

 

 

The following modules are supported on fixed ports on the Cisco ASR 9001 and Cisco ASR 9001-S:

SFP-10G-ZR

DWDM SFP10G-3033 through DWDM SFP10G-6141

ONS-SC+-10G-C

Cisco ASR 9001 and Cisco ASR 9001-S Routers Hardware Installation Guide

A-5

Page 119
Image 119
Cisco Systems ASR 9001-S manual RP Port Specifications, Power Consumption Specifications