1-17
Cisco ASR 9001 and Cisco ASR 9001-S Routers Hardware Installation Guide
Chapter1 Preparing for Installation
Site Requirement Guidelines
Figure1-18 AC Power Cord CAB-9K10A-EU
Figure1-19 AC Power Cord SFS-250V-10A-IS
DC Powered Router
Connections to DC power modules are rated at 20 A maximum. The system accepts a nominal input voltage
of –48VDC wi th an operational tolerance range of –40.5 VDC to –72 VDC. One dedicat ed,
commensurately rated DC power source is required for each power module connection.
Power connections to the each DC power module requires two cables: one source cable and one return
cable.
For DC power cables, we recommend that you use 20-A-rated, high-strand-count copper wire cables.
The length of the cables depends on your router location from the source power.
Note DC power cables are not available from Cisco, but they are available from external commercial cable
vendors.
You must terminate DC power cables using terminal blocks. The terminal blocks are supplied along with
the DC power supply modules from Cisco. The terminal block part number is PC 5/2-STF-7.62 BD:+,-
from Phoenix contact.
Connector: WS 002
Cordset rating: 10A, 250 V
Length: 8 ft 2 in. (2.5 m)
Plug:
M2511
332625
Cordset rating: 10 A, 250V
Length: 8 ft 2 in. (2.5 m)
Plug:
EL 212
(SI-32)
332624
Connector: WS 002