Chapter 4 Troubleshooting the Installation

Troubleshooting the Power Subsystem

Additional Power Subsystem Troubleshooting Information

This section contains additional troubleshooting information to help you isolate the cause of a power problem.

Hardware and Software Identification

The power modules have software IDs that differ from the hardware ID labels on the chassis. Table 4-2is a table for converting power module hardware IDs to software IDs.

Table 4-2 Power Module Hardware and Software IDs

Hardware ID

PS0 M0

PS0 M1

Software ID

PM0

PM1

Obtaining Temperature and Environmental Information

If both the RP and the fan tray are operating, all internal correct DC voltages are present.

Enter the show environment command at the router admin prompt to display temperature and voltage information for each installed card, fan tray, and power module as shown in this example:

RP/0/RSP0/CPU0:router(admin)#show environment

Sat Apr 15 04:57:35.185 UTC

Temperature Information

---------------------------------------------

R/S/I

Modules

Sensor

(deg C)

0/RSP0/*

 

 

 

 

host

Inlet0

31.1

 

host

Inlet1

30.3

 

host

Hotspot0

45.8

 

host

Hotspot1

38.3

 

host

Hotspot2

45.5

 

host

Hotspot3

46.0

0/0/*

 

 

 

 

ep0

Inlet0

33.1

 

ep0

Hotspot0

38.5

 

ep1

Inlet0

33.6

 

ep1

Hotspot0

37.5

 

host

Hotspot0

43.5

 

host

Hotspot1

37.8

 

host

Hotspot2

45.7

 

host

Hotspot3

41.6

 

host

Hotspot4

45.9

 

host

Inlet0

36.0

Voltage

Information

 

 

---------------------------------------------

 

R/S/I

Modules Sensor

(mV)

Margin

Cisco ASR 9001 and Cisco ASR 9001-S Routers Hardware Installation Guide

4-6

Page 92
Image 92