Cisco Systems MDS 9000 show module slot diag uptime, Specifies the slot number for the module

Models: MDS 9000

1 194
Download 194 pages 60.55 Kb
Page 120
Image 120
show module

Chapter 20 Show Commands

show module

show module

To verify the status of a module, use the show module command.

show module [slot diag uptime]

Syntax Description

Defaults

Command Modes

Command History

Usage Guidelines

slot

Specifies the slot number for the module.

 

 

diag

Displays module-related information.

 

 

uptime

Displays the length of time that the modules have been functional in the

 

switch.

 

 

None.

 

EXEC mode.

 

This command was modified in Cisco MDS SAN-OS Release 1.3(4).

If your chassis has more than one switching module, you will see the progress check if you issue the show module command several times and view the status column each time.

The switching module goes through a testing and an initializing stage before displaying an ok status.

The following table describes the possible states in which a module can exist.

show module Output

Description

 

 

powered up

The hardware has electrical power. When the hardware is powered up, the

 

software begins booting.

 

 

testing

The module has established connection with the supervisor and the switching

 

module is performing bootup diagnostics.

 

 

initializing

The diagnostics have passed and the configuration is being downloaded.

 

 

failure

The switch detects a switching module failure on initialization and

 

automatically attempts to power-cycle the module three (3) times. After the

 

third attempt it continues to display a failed state.

 

 

ok

The switch is ready to be configured.

 

 

power-denied

The switch detects insufficient power for a switching module to power up.

 

In this case, issue a show environment power command to determine power

 

consumption issues.

 

 

active

This module is the active supervisor module and the switch is ready to be

 

configured.

 

 

 

Cisco MDS 9000 Family Command Reference

20-120

78-16088-01, Cisco MDS SAN-OS Release 1.3

Page 120
Image 120
Cisco Systems MDS 9000 show module slot diag uptime, Specifies the slot number for the module, switch, 20-120, None