Cisco Systems MDS 9000 manual 20-84, switch# show interface fc2/5 transceiver details

Models: MDS 9000

1 194
Download 194 pages 60.55 Kb
Page 84
Image 84
switch# show interface fc2/5 transceiver details

Chapter 20 Show Commands

show interface

Temperature

:

34.98

Celsius

Voltage

:

3.31

Volt

Current

:

7.24

mA

Optical Tx

Power :

-5.99 dBm

 

Optical Rx

Power : -23.01 dBm

 

Note: ++ high-alarm; +

high-warning; --

low-alarm; - low-warning

switch# show interface fc2/5 transceiver details

fc2/5 fcot is present

 

 

name is CISCO-INFINEON

 

 

part number is

V23848-M305-C56C

 

revision is A3

 

 

 

serial number is 30000474

 

fc-transmitter

type is short wave laser

 

cisco extended

id is unknown (0x0)

 

SFP Detail Diagnostics Information

----------------------------------------------------------------------------

 

Alarms

 

Warnings

High

Low

High

Low

----------------------------------------------------------------------------

Temperature

34.98

C

105.00

C

211.00

C

100.00

C

216.00

C

Voltage

3.31

V

3.71

V

2.80

V

3.64

V

2.97

V

Current

7.24

mA

19.97

mA

3.07

mA

14.85

mA

4.61

mA

Tx

Power

-5.99

dBm

-3.00

dBm

-10.51

dBm

-4.00

dBm

-9.51

dbm

Rx

Power

-23.01

dBm

1.00

dBm

-23.98

dBm

0.00

dBm

-18.86

dBm

----------------------------------------------------------------------------

Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning

The following example displays calibration information for the tranceiver on a Fibre Channel interface.

switch# show interface fc2/5 transceiver calibrations fc2/5 fcot is present

name is CISCO-INFINEON

part number is V23848-M305-C56C revision is A3

serial number is 30000474 fc-transmitter type is short wave laser cisco extended id is unknown (0x0)

SFP is internally calibrated

The following example displays information for a Fibre Channel tunnel interface.

switch# show interface fc-tunnel 200

fc-tunnel

200

is up

 

Dest

IP

Addr: 200.200.200.7

Tunnel ID: 200

Source IP

Addr: 200.200.200.4

LSP ID: 1

Explicit Path

Name:

 

 

Cisco MDS 9000 Family Command Reference

20-84

78-16088-01, Cisco MDS SAN-OS Release 1.3

Page 84