Image 20
Power Options and Requirements

Chapter 1 Overview

Power Options and Requirements

Power Options and Requirements

This section includes the following information:

Power Options

Current Draw Requirements

Installing Surge Suppressors on Output Device Connections

Connect Reader Devices with Module Power Off

Power Options

Table 1-3summarizes the power options for each module. The Cisco Physical Access Gateway supports Power over Ethernet (PoE) and DC power. All other modules support DC power only.

The DC power connections on each module are Voltage In (VIN) and Ground (GND).

For information on configuring PoE, see the documentation for your network switch. Your switch must support PoE and be properly configured to use this feature with the Cisco Physical Access Gateway.

Table 1-3

Power Options for the Cisco Physical Access Control Modules

 

 

 

 

Module

 

Power over Ethernet (PoE)

12 through 24V DC

 

 

 

Cisco Physical Access Gateway

Supported

Supported

 

 

 

Cisco Reader Module

Not Supported

Supported

 

 

 

Cisco Input Module

Not Supported

Supported

 

 

 

Cisco Output Module

Not Supported

Supported

 

 

 

 

Current Draw Requirements

Each Cisco Physical Access Control module requires a minimum amount of available power, as described in Table 1-4. The current draw requirements listed in Table 1-4account for inefficiencies in power supplies and are to be used for power budgeting. The requirements do not represent actual power usage.

 

 

 

 

Table 1-4

Current Draw Requirements for the Cisco Physical Access Control Modules

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Current Draw

 

 

 

 

 

 

Module

 

Requirement

Notes

 

 

 

 

 

 

 

 

 

 

 

Cisco Physical Access Gateway

1.5A

1.5A is required for the Gateway module only.

 

 

 

 

 

 

 

Add an additional 1A if a reader or lock is

 

 

 

 

 

 

 

attached to the module.

 

 

 

 

 

 

 

 

 

 

 

Cisco Reader Module

1A

1A is required for the Reader module only. Add

 

 

 

 

 

 

 

an additional 1A if a reader or lock is attached to

 

 

 

 

 

 

 

the module.

 

 

 

 

 

 

 

 

 

 

 

Cisco Input Module

1A

N/A

 

 

 

 

 

 

 

 

 

 

 

Cisco Output Module

1A

N/A

 

 

 

 

 

 

 

 

 

 

 