Chapter 3 Connecting a Cisco Reader Module

Installing the Cisco Reader Module

Step 4 Connect one or two door reader devices to the Wiegand interface using one of the following configurations:

Connect a single door reader using all 10 Wiegand interface pins.

Connect one or two door readers using 5-pin Wiegand interface connections (for installations where a 5-pin interface is sufficient).

Figure 3-8shows the location of the Wiegand interface connections. The table describes the connections for 10-pin and 5-pin reader interface connections. The wire connectors from the reader device are shown in parentheses. If attaching a second reader, use the alternative connections shown in the column on the far right.

Figure 3-8 Wiegand Interface on the Gateway and Reader Modules

10

 

8

9

6

 

7

 

4

 

2

 

5

 

 

 

 

3

1

271603

 

 

Chassis

 

One Reader

First Reader in a

Second Reader in a

 

 

 

Label

Description

10 Wire Connection

5 Wire Connection

5 Wire Connection

 

 

 

 

 

 

 

 

 

 

PWR

+12v

PWR (red) 1

PWR (red)

PWR (red)

 

 

 

GND

Ground

GND (black)

GND (black)

GND (black)

 

 

 

 

 

 

 

 

 

 

 

 

D0

Data 0

D0 (green)

D0 (green)

----------

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1/CLCK

Data 1

D1/CLCK (white)

D1/CLCK (white)

----------

 

 

 

 

 

 

 

 

 

 

 

 

 

DRTN

Shield

DRTN (shield)

DRTN (shield)

DRTN (shield)

 

 

 

 

 

 

 

 

 

 

 

 

GRN

Output 2

GRN (orange)

GRN (orange)

----------

 

 

 

 

 

 

 

 

Cisco Physical Access Gateway User Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OL-20932-02

 

 

 

 

 

3-9

 

 

 

 

 

 

 

 