Cisco Systems OL-20932-02 manual 3-11

Models: OL-20932-02

1 94
Download 94 pages 10.95 Kb
Page 59
Image 59
3-11

Chapter 3 Connecting a Cisco Reader Module

Installing the Cisco Reader Module

Figure 3-10 Input Connections: Cisco Physical Access Gateway and Reader Module

271592

3

4

1

2

1

2

1

2

1

2

3

4

Positive Input Connections

Positive connection to an Input device.

Ground Input Connections

Ground connection to an Input device.

TM

Tamper input: an unsupervised input that raises a “tamper” alarm when the circuit is open. Can be configured as a general input device using the Cisco Physical Access Manager. The corresponding LED is red when circuit is open (when no input is connected).

PF

Power fail input: an unsupervised input that raises a “power fail” alarm when the circuit is open. Can be configured as an additional unsupervised port. The corresponding LED is red when circuit is open (when no input is connected).

Step 6 Connect output devices to the module:

a.Insert three-pin connector plugs into the output ports (Figure 3-11).

b.Connect the wires from the output devices.

Common (C) is always used, and either NC or NO is used to complete the connection.

 

 

Cisco Physical Access Gateway User Guide

 

 

 

 

 

 

OL-20932-02

 

 

3-11

 

 

 

 

 

Page 59
Image 59
Cisco Systems OL-20932-02 manual 3-11