Cisco Systems OL-20932-02 manual 5 Power Connections for the Cisco Output Module

Models: OL-20932-02

1 94
Download 94 pages 10.95 Kb
Page 75
Image 75
Figure 5-5 Power Connections for the Cisco Output Module

Chapter 5 Connecting a Cisco Output Module

Installing the Cisco Output Module

Figure 5-5 Power Connections for the Cisco Output Module

Manual background271599

1

2

1

2

DC power GND (ground)

Connects the DC ground wire to the module.

DC power Voltage In (VIN)

Connects the DC Voltage In (VIN) wire to the module.

Step 3 Connect the module to the CAN bus:

a.Insert a three-pin connector plug into the CAN1 port, as shown in Figure 5-6.

b.Connect the CAN wires to the CAN bus, as shown in Figure 5-7

c.Turn the CAN terminator ON if the device is the last device in a CAN wiring bus.

Note The CAN terminator switch in included on the Reader, Input and Output modules only (the Gateway is always the first device in the CAN bus). Set the terminator switch to OFF for all other modules in the CAN bus.

Note The CAN2 interface is not supported in this release.

See the “Optional Expansion Modules” section on page 1-5for more information.

Cisco Physical Access Gateway User Guide

 

OL-20932-02

5-7

 

 

 

Page 75
Image 75
Cisco Systems OL-20932-02 manual 5 Power Connections for the Cisco Output Module