iDP3221 User’s Manual
When sending print data, note these:
(1)Each string of bar code data must begin with a codeset select character (CODE A, CODE B, or CODE C), which selects the first codeset to use.
(2)Every special character is specified by a combination of two characters: a brace "{" followed by one character. A brace "{" itself is specified by two consecutive braces "{{."
Special characters
Hex. | ASCII | Codeset A | Codeset B | Codeset C |
|
|
|
|
|
7B 53 | { S | SHIFT | SHIFT | – |
7B 41 | { A | – | CODE A | CODE A |
7B 42 | { B | CODE B | – | CODE B |
7B 43 | { C | CODE C | CODE C | – |
7B 31 | { 1 | FNC1 | FNC1 | FNC1 |
7B 32 | { 2 | FNC2 | FNC2 | – |
|
|
|
|
|
7B 33 | { 3 | FNC3 | FNC3 | – |
|
|
|
|
|
7B 34 | { 4 | FNC4 | FNC4 | – |
|
|
|
|
|
7B 7B | { { | { | { | { |
|
|
|
|
|
<Example> | To print "No." in codeset B, followed by "123456" in codeset C, send the |
| following data string: |
| GS k <73><10><7BH 42H> "No." <7BH 43H><12><34><56> |
•If the printer finds a string of bar code data that does not begin with a codeset select character, it immediately aborts the command processing and handles the subsequent data as normal data.
•If the printer received a character that is not available in the currently selected codeset, it immediately aborts the command processing and handles the subsequent data as normal data.
•An HRI character corresponding to either a Shift character or a code select character is not printed. An HRI character for either a function character or a control character is treated as a space character.
[Sample Program] | [Print Results] |
LPRINT CHR$ (&H1D) ; "H" ; CHR$ (2) ;
LPRINT CHR$ (&H1D) ; "k" ;
LPRINT CHR$ (4) ;
LPRINT "123" ; CHR$ (0) ;
107 | CITIZEN |